Technical Specifications
Size
108.2 mm x 61.5 mm x 43.2 mm (4.29 in x 2.44 in x1.7 in) with Alligator Clip 108.2 mm x 61.5 mm x 37.8 mm (4.29 in x 2.44 in x 1.49 in) with Klick Fast Stud
Weight
With Catalytic LEL: 189 g (6.7 oz) with Alligator Clip, 173 g (6.1 oz) with Klick Fast Stud With IR LEL: 186 g (6.6 oz) with Alligator Clip, 170 g (6.0 oz) with Klick Fast Stud
Working Temperature
-40°C to 60°C (-40°F to 140°F) and -20°C to 60°C ( -4°F to 140°F ) with Catalytic LEL sensor
Working Humidity
5% to 95%
Ingress Protection
IP66, IP68
Alarms and Type
Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, Negative Drift, Over Limit, Multi-alarm
Self-Test
Perform diagnostic of sensor, circuitry on activation;
Activated detector automatically performs analog sensor diagnostic every 10 minutes, digital sensor diagnostic every second
Typical Battery Life
40 days @ 8 hours of use per day with IR LEL 15 hours with Catalytic LEL (with NDIR CH4 sensor)
Connected Worker
Bluetooth® Low Energy (BLE) – Ability to connect to Honeywell’s Safety Communicator App, Device Configurator App and Safety Suite Device Configurator Software
User Options
• Change High, Low, TWA and STEL alarm set points • Latching alarms
• Set Calibration and/or bump test reminders
• Assign worker and location assignments
• Always on
User options only available via Device Configurator and Safety Suite Device Configurator
Certifications and Approvals
Device Warranty
ATEX, IEC Ex, contains FCCID, contains IC, CSA approval pending
Three-year warranty for sensors and detector
Sensor Specifications
Gas Name
CO
SO2
Measuring Range
0 to 150 ppm
Resolution
1 ppm
0.1 ppm
Working Temperature
0 to 2000 ppm
-40°C to 60°C (-40°F to 140°F)
H2S
0 to 200 ppm
1 ppm (can set to 0.1ppm)
-40°C to 60°C (-40°F to 140°F)
-20°C to 50°C (-4°F to 122°F) intermittent -40°C to 55°C (-40°F to 131°F)
O2
0 to 30% VOL
0.1% VOL
NDIR-CH4
Catalytic LEL
0 to 100% LEL
1% LEL
-40°C to 60°C (-40°F to 140°F)
0 to 100% LEL
1% LEL
-40°C to 60°C (-40°F to 140°F)
-20°C to 60°C (-4°F to 140°F)